TRM (Thailand Reference Material)

     TRM (Thailand Reference Material) is a certified reference material issued by the National Institute of Metrology (Thailand), NIMT and its designated institute. TRM with a roof shape logo is a registered trademark of NIMT with the department of intellectual property, Thailand. TRMs are produced to the highest standards according to ISO Guide 34 ensuring their consistent quality. TRMs are produced with a well-defined traceability linkage to SI unit (Mole). The traceability is established via NIMT criteria using metrologically valid procedures for the certification of reference material given by NIMT.

Static

TRM Product:
110 Units
Last Modify:
2 Nov 2018
Visitor:
828,542

TRM (Thailand Reference Material)

Elements in Human Serum
[TRM-C-2001]
Range : Ca 92.9 mg/kg K 168 mg/kg Mg 21.8 mg/kg
Uncertainty : 6.3 mg/kg 11 mg/kg 1.3 mg/kg
Ethanol in Air
[TRM-C-3010]
Range : 100 - 200 µmol/mol
Uncertainty : 1.0 %relative
Total Cholesterol in Frozen Human Serum
[TRM-C-5001]
Range : 2.05 mg/kg
Uncertainty : 6.0% relative
Elements in Soil
[TRM-E-2001]
Range : Cd 0.85 mg/kg,Cu 27.7 mg/kg,Ni 43.7 mg/kg,Pb 29.5 mg/kg,Zn 69.6 mg/kg
Uncertainty : 0.10 mg/kg,2.1 mg/kg,2.8 mg/kg, 1.9 mg/kg,7.8 mg/kg
Trace Elements in Drinking Water
[TRM-E-2002]
Range : Cd 0.0050 mg/kg Cu 0.504 mg/kg Pb 0.061 mg/kg Zn 0.632 mg/kg
Uncertainty : 0.0003 mg/kg 0.011 mg/kg 0.004 mg/kg 0.018 mg/kg
Mercury in Drinking Water
[TRM-E-2003]
Range : 528 ng/kg
Uncertainty : 41 ng/kg
Oxygen in Nitrogen
[TRM-E-3010]
Range : 1-30 cmol/mol
Uncertainty : 0.25-0.45% relative
Oxygen in Nitrogen
[TRM-E-3011]
Range : 2-30 cmol/mol
Uncertainty : 0.5% relative
Carbon dioxide in Nitrogen
[TRM-E-3020]
Range : 1-15 cmol/mol
Uncertainty : 1.0% relative
Carbon dioxide in Nitrogen
[TRM-E-3021]
Range : 0.5-20 cmol/mol
Uncertainty : 1.0% relative
Methane in Nitrogen
[TRM-E-3030]
Range : 1-15 cmol/mol
Uncertainty : 0.35% relative
Methane in Nitrogen
[TRM-E-3031]
Range : 1-10 cmol/mol
Uncertainty : 0.7% relative
Methane in Air
[TRM-E-3032]
Range : 0.5-10 cmol/mol
Uncertainty : 1.0% relative
Methane in Nitrogen
[TRM-E-3033]
Range : 100-1000 µmol/mol
Uncertainty : 1.0% relative
CO in Air
[TRM-E-3040]
Range : 50 - 5000 µmol/mol
Uncertainty : 1.0 %relative
Sulfur Dioxide in Nitrogen
[TRM-E-3050]
Range : 500 - 2,000 µmol/mol
Uncertainty : 0.5% relative
Propane in Nitrogen
[TRM-E-3061]
Range : 200-5,000 µmol/mol
Uncertainty : 0.5% relative
Propane in Nitrogen
[TRM-E-3062]
Range : 0.5-10 cmol/mol
Uncertainty : 1.0 %relative
Propane in Air
[TRM-E-3063]
Range : 0.5-10 cmol/mol
Uncertainty : 1.0 %relative
Nitrogen Monoxide in Nitrogen
[TRM-E-3070]
Range : 1,000 - 10,000 µmol/mol
Uncertainty : 1.0 %relative
Organochlorine Pesticides in Soil
[TRM-E-5001]
Range : Endosulfan II 0.43 mg/kg
Uncertainty : 14% Relative
Pure pork meat
[TRM-F-1001]
Range : 1000 g/kg
Uncertainty : N/A
Pure beef meat
[TRM-F-1002]
Range : >998.8 g/kg
Uncertainty : N/A
Element in Glutinous Rice Powder
[TRM-F-2001]
Range : Cd 0.69 mg/kg Cr 1.5 mg/kg Mn 7.8 mg/kg Zn 21.2 mg/kg
Uncertainty : 0.06 mg/kg 0.1 mg/kg 1.0 mg/kg 1.0 mg/kg
Trace and Essential Elements in Prawn
[TRM-F-2002]
Range : Cd 2.05 mg/kg Cu 49 mg/kg Pb 1.80 mg/kg Zn 81 mg/kg
Uncertainty : 0.11 mg/kg 0.2 mg/kg 0.10 mg/kg 4 mg/kg
Arsenic in White Rice Flour
[TRM-F-2003]
Range : Total As 100 µg/kg
Uncertainty : 7 µg/kg
Total Malachite Green in Freeze Dried Prawn
[TRM-F-5001]
Range : 18.35 µg/kg
Uncertainty : 10.00% relative
Alfatoxins in Peanut Butter
[TRM-F-5002]
Range : 2-10 ng/g
Uncertainty : 8-10% relative
Melamine in cracker
[TRM-F-5003]
Range : 1.56 mg/kg
Uncertainty : 9% relative
Clenbuterol in feed
[TRM-F-5004]
Range : 71.9 µg/kg
Uncertainty : 5.43 % relative
Salbutamol in feed
[TRM-F-5005]
Range : 79.5 µg/kg
Uncertainty : 14.21 % relative
Melamine in Milk Powder
[TRM-F-5006]
Range : 1.03 mg/kg
Uncertainty : 16% relative
Moisture in Material (Sample:Paddy)
[TRM-F-6001]
Range : 10% MC
Uncertainty : (0.3 to 0.5) % MC
Moisture in Material (Sample:Paddy)
[TRM-F-6002]
Range : 12% MC
Uncertainty : (0.3 to 0.5) % MC
Moisture in Material (Sample:Paddy)
[TRM-F-6003]
Range : 14% MC
Uncertainty : (0.3 to 0.5) % MC
Moisture in Material (Sample:Paddy)
[TRM-F-6004]
Range : 16% MC
Uncertainty : (0.3 to 0.5) % MC
Moisture in Material (Sample:Paddy)
[TRM-F-6005]
Range : 18% MC
Uncertainty : (0.3 to 0.5) % MC
Moisture in Material (Sample:Rice)
[TRM-F-6006]
Range : 10% MC
Uncertainty : (0.3 to 0.5) % MC
Moisture in Material (Sample:Rice)
[TRM-F-6007]
Range : 12% MC
Uncertainty : (0.3 to 0.5) % MC
Moisture in Material (Sample:Rice)
[TRM-F-6008]
Range : 14% MC
Uncertainty : (0.3 to 0.5) % MC
Moisture in Material (Sample:Rice)
[TRM-F-6009]
Range : 16% MC
Uncertainty : (0.3 to 0.5) % MC
Moisture in Material (Sample:Rice)
[TRM-F-6010]
Range : 18% MC
Uncertainty : (0.3 to 0.5) % MC
Element in Acrylonitrile Butadiene Styrene (ABS) Plastic
[TRM-M-2001]
Range : Cd 10.1 mg/kg Cr 21 mg/kg Pb 82 mg/kg Hg 102 mg/kg
Uncertainty : 0.5 mg/kg 1 mg/kg 4 mg/kg 7 mg/kg
Elements in Acrylonitrile Butadiene Styrene (ABS) Plastic, High Levels
[TRM-M-2002]
Range : Cd 102 mg/kg Cr 172 mg/kg Pb 837 mg/kg Hg 1025 mg/kg
Uncertainty : 4 mg/kg 7 mg/kg 36 mg/kg 61 mg/kg
Pork DNA solution
[TRM-S-1001]
Range : 1.0x105 copy number/mL
Uncertainty : 6.0x103 copy number/mL
MON810 plasmid DNA
[TRM-S-1002]
Range : 1.04 copy number ratio
Uncertainty : 0.061 copy number ratio
Enzyme a-amylase
[TRM-S-1003]
Range : 382.8-457.2 U/L
Uncertainty : 37.2 U/L
Secondary pH standards (pH1.10) 0.01 N Hydrochloric acid
[TRM-S-2001]
Range : 1.08-1.12 pH
Uncertainty : 0.02 pH
Secondary pH standards (pH1.68)Tetroxalate pH standard
[TRM-S-2002]
Range : 1.66-1.70 pH
Uncertainty : 0.006 pH
Secondary pH standards (pH4.01)Phthalate pH standard
[TRM-S-2003]
Range : 3.99-4.02 pH
Uncertainty : 0.006 pH
Secondary pH standards (pH6.86)Phosphate pH standard
[TRM-S-2004]
Range : 6.85-6.88 pH
Uncertainty : 0.006 pH
Secondary pH standards (pH7.01)Phosphate pH standard
[TRM-S-2005]
Range : 6.99-7.03 pH
Uncertainty : 0.006 pH
Secondary pH standards (pH9.18)Tetraborate pH standard
[TRM-S-2006]
Range : 9.17-9.20 pH
Uncertainty : 0.007 pH
Secondary pH standards (pH10.01)Carbonate pH standard
[TRM-S-2007]
Range : 9.99-10.02 pH
Uncertainty : 0.006 pH
Secondary pH standards (pH11.72)Alkaline phosphate pH standard
[TRM-S-2008]
Range : 11.70-11.74 pH
Uncertainty : 0.02 pH
Potassium Dichromate Standards
[TRM-S-2009]
Range : 20 mg/kg, 40 mg/kg, 60 mg/kg, 80 mg/kg, 100 mg/kg
Uncertainty : 0.01 A
Potassium lodide Standard Solution
[TRM-S-2010]
Range : 10 g/L
Uncertainty : 0.5 nm
Zinc Standard Solution
[TRM-S-2011]
Range : 10,000 mg/kg
Uncertainty : 1% relative
Cadmium Standard Solution
[TRM-S-2012]
Range : 10,000 mg/kg
Uncertainty : 1% relative
Chloride Standard Solution
[TRM-S-2013]
Range : 100 mg/kg
Uncertainty : 1% relative
Sodium Standard Solution
[TRM-S-2014]
Range : 100 mg/kg
Uncertainty : 1% relative
Arsenic standard solution
[TRM-S-2015]
Range : 1000 mg/kg
Uncertainty : 0.2%
pH of ethanol
[TRM-S-2016]
Range : 6-8 pH
Uncertainty : 0.5 pH
Secondary Electrolytic Conductivity Solution (0.001 mol/l KCl)
[TRM-S-2017]
Range : 147 µS/cm
Uncertainty : 0.8 %relative
Secondary electrolytic conductivity solution
[TRM-S-2018]
Range : 12.88 mS/cm
Uncertainty : 0.5 %relative
Secondary electrolytic conductivity solution
[TRM-S-2019]
Range : 1413 µS/cm
Uncertainty : 0.5 %relative
(Primary) Phthalate buffer solution
[TRM-S-2020]
Range : 3.99 - 4.02 pH
Uncertainty : 0.005 pH
(Primary) Phosphate buffer solution
[TRM-S-2021]
Range : 6.85 - 6.88 pH
Uncertainty : 0.005 pH
(Primary) Borate buffer solution
[TRM-S-2022]
Range : 9.16 - 9.20 pH
Uncertainty : 0.005 pH
Electrolytic conductivity of ethanol
[TRM-S-2023]
Range : 0.1-1 uS/cm
Uncertainty : 5%relative
Working pH standard
[TRM-S-2027]
Range : 3.99-4.02 pH
Uncertainty : 0.01 pH
Working pH standard
[TRM-S-2028]
Range : 6.85-6.88 pH
Uncertainty : 0.01 pH
Working pH standard
[TRM-S-2029]
Range : 9.17-9.20 pH
Uncertainty : 0.01 pH
Working pH standard
[TRM-S-2031]
Range : 9.99-10.02 pH
Uncertainty : 0.01 pH
Working pH standard
[TRM-S-2032]
Range : 1.08-1.12 pH
Uncertainty : 0.01 pH
Working pH standard
[TRM-S-2033]
Range : 1.66-1.70 pH
Uncertainty : 0.01 pH
Working pH standard
[TRM-S-2034]
Range : 6.99-7.03 pH
Uncertainty : 0.01 pH
Working pH standard
[TRM-S-2035]
Range : 11.70-11.74 pH
Uncertainty : 0.01 pH
Sucrose Standard Solution
[TRM-S-5001]
Range : 5.00 %Brix, 1.34026 nD
Uncertainty : 0.010 % Brix, 0.00006 nD
Sucrose Standard Solution
[TRM-S-5002]
Range : 10.00 %Brix, 1.34782 nD
Uncertainty : 0.010 % Brix, 0.00006 nD
Sucrose Standard Solution
[TRM-S-5003]
Range : 20.00 %Brix, 1.36384 nD
Uncertainty : 0.010 % Brix, 0.00006 nD
Sucrose Standard Solution
[TRM-S-5004]
Range : 30.00 %Brix, 1.38115 nD
Uncertainty : 0.010 % Brix, 0.00006 nD
Sucrose Standard Solution
[TRM-S-5005]
Range : 50.00 %Brix, 1.42009 nD
Uncertainty : 0.010 % Brix, 0.00007 nD
Sucrose Standard Solution
[TRM-S-5006]
Range : 60.00 %Brix, 1.44193 nD
Uncertainty : 0.010 % Brix, 0.00006 nD
Benzene in methanol
[TRM-S-5007]
Range : 1,000 mg/L
Uncertainty : 1.4% relative
Ethylbenzene in methanol
[TRM-S-5008]
Range : 1,000 mg/L
Uncertainty : 1.1% relative
Toluene in methanol
[TRM-S-5009]
Range : 1,000 mg/L
Uncertainty : 1.4% relative
o-xylene in methanol
[TRM-S-5010]
Range : 1,000 mg/L
Uncertainty : 2.2% relative
m-xylene in methanol
[TRM-S-5011]
Range : 1,000 mg/L
Uncertainty : 1.0% relative
p-xylene in methanol
[TRM-S-5012]
Range : 1,000 mg/L
Uncertainty : 1.3% relative
Organochlorine
[TRM-S-5013]
Range : 100 mg/kg
Uncertainty : 3% relative
Organophosphate Set 1
[TRM-S-5014]
Range : 100 mg/kg
Uncertainty : 5% relative
Organophosphate Set 2
[TRM-S-5015]
Range : 100 mg/kg
Uncertainty : 3% relative
Acaricide
[TRM-S-5016]
Range : 100 mg/kg
Uncertainty : 3% relative
Carbamate
[TRM-S-5017]
Range : 100 mg/kg
Uncertainty : 3% relative
Pyrethroid Pesticide Mix set 1
[TRM-S-5018]
Range : 100 mg/kg
Uncertainty : 2 % relative
Organophosphate Pesticide Mix set3
[TRM-S-5019]
Range : 100 mg/kg
Uncertainty : 4 % relative
Organophosphate Pesticide Mix set 4
[TRM-S-5020]
Range : 100 mg/kg
Uncertainty : 4 % relative
Organochlorine Pesticide Mix set 2
[TRM-S-5021]
Range : 100 mg/kg
Uncertainty : 2 % relative
Pyrethroid Pesticide Mix set 2
[TRM-S-5022]
Range : 100 mg/kg
Uncertainty : 3 % relative
Organophosphate Pesticide Mix set 5
[TRM-S-5023]
Range : 100 mg/kg
Uncertainty : 3 % relative
Acaricide Pesticide Mix set 2
[TRM-S-5024]
Range : 100 mg/kg
Uncertainty : 2 % relative
Insecticide Pesticide Mix set 1
[TRM-S-5025]
Range : 100 mg/kg
Uncertainty : 2 % relative
Sucrose Standard Solution
[TRM-S-5026]
Range : 0.01 % Brix
Uncertainty : 2.0 % relative
Sucrose Standard Solution
[TRM-S-5027]
Range : 0.02 % Brix
Uncertainty : 1.4 % relative
Sucrose Standard Solution
[TRM-S-5028]
Range : 0.03 % Brix
Uncertainty : 0.5 % relative
Sucrose Standard Solution
[TRM-S-5029]
Range : 0.04 % Brix
Uncertainty : 0.6 % relative
Sucrose Standard Solution
[TRM-S-5030]
Range : 0.05 % Brix
Uncertainty : 0.8 % relative
Sucrose Standard Solution
[TRM-S-5031]
Range : 40.00 %Brix, 1.39986 nD
Uncertainty : 0.01 % Brix, 0.00007 nD
Sucrose Standard for Optical Measurements
[TRM-S-5032]
Range :
Uncertainty :

Back to Top

National Institute of Metrology (Thailand)
Contact Customer Service
Email :
Tel. 02 577 5100 Fax. 02 577 3659
Tel. +660 2577 5100 Fax. +660 2577 3659
3/4-5 Moo 3 Tambol Klonghar Amphur Klong Luang Pathum Thani 12120 Thailand
Powered By : Information Technology (NIMT)